andes_ae350_n25 negative control: uart1 removed (2026-11-08)

Same firmware (--features ae350-uart) and smoke script, with uart1 removed from the chip (the andes_ae350_n25.yaml copy here, loaded through a one-line system manifest chip: andes_ae350_n25.yaml with labwired test --system). FAIL 1/6: the first uart1 access (the LCR write at 0xF030002C) is a memory access violation and the run stops, so no UART bytes appear, the LSR/divisor and pass words at 0x1004..0x100C are never written, and the run does not reach max_steps. Only the MUL word at 0x1000 (written before any peripheral access) holds. The UART and register checks therefore depend on the modelled uart1.

The round's first real run also failed, before any firmware executed: the chip declared size: 0x20, which the descriptor parser rejects ("Invalid size format: invalid multiple"); it was changed to size: 32B. That run's logs were overwritten by the passing run.