ACS712 current sensor
acs712 models the 5 A ACS712ELCTR-05B with its typical 25 °C transfer.
The current stimulus is in amperes, from −5 to +5, initially zero.
OUT is VCC/2 + 0.185 V/A × current at a 5 V supply. Both offset and
sensitivity scale with the supplied rail. The real MCU ADC model converts
the resulting millivolts; a stimulus never writes ADC result registers.
On an Uno this puts OUT on ADC1/A1. The hosted catalog module has VCC, GND and OUT signal pads. Its high-current conductor is a stimulus source in this model, not an automatic series connection to a motor winding.
| Modeled | Boundary |
|---|---|
| Signed current and ratiometric output | 5 A variant only; 20 A/30 A variants have different sensitivity |
| ADC voltage routing and firmware conversion | Millivolt quantization; no sensor noise, bandwidth or thermal drift |
| Range validation | Inputs outside −5…+5 A are refused |
desk_controller_inputs sweeps the signed transfer at 4.5/5.0/5.5 V and
executes Arduino analogRead for 0.5 A, 2.5 A and −2.5 A. This is model
validation against the published transfer, not a physical sensor capture.
Source: Allegro ACS712 datasheet.