EFM32PG1 attempt 01: incorrect USART0 base
The first smoke fixture reused the EFM32PG12 USART0 address (0x4000c000).
The imported EFM32PG1 descriptor places USART0 at 0x40010000, so the write
faulted as unmapped MMIO before any UART bytes were emitted.
This run executed 100,000 instructions, but the UART assertion failed and the
result reported a precise BusFault/HardFault at 0x4000c00c. It is preserved
here as a failed attempt and is not counted in the active scoreboard. The
fixture was corrected to use the PG1 descriptor's USART0 base before the
measured inventory refresh.