FocalTech FT9001 smoke attempt history
Attempt 01
The first run failed at run_smoke with config_error before executing any
instruction: the smoke script declared schema_version: "1.0", but
uart_injections require "1.2". The CLI and firmware built. The metrics and
logs are retained under attempt-01/.
The script was bumped to "1.2" and rerun.
Attempt 02
The platform booted, stopped at max_steps, and printed every expected UART
line. The uart_ordered and stop-reason assertions passed. The first
assertion failed because it used \A, which LabWired's uart_regex engine
(crates/cli/src/regex.rs) does not support. That engine anchors with ^.
Retained under attempt-02/.
The pattern was changed to ^FT9001 SMOKE\r\n and rerun; the current result
is under ../../metrics/focaltech_ft9001/.
Pre-IRQ-removal pass
Before narrowing the imported descriptor to drop USART2's unmodelled IRQ 33,
the passing metrics, logs and simulator artifacts were archived under
2026-11-06-pre-irq-removal/. That run executed 4,000,000 instructions and
passed all three smoke assertions. The current post-change evidence remains
under ../../metrics/focaltech_ft9001/.
CPM, reset and TRNG models (2026-11-15)
The passing USART2-only metrics before this change are archived under
2026-11-15-before-sys-blocks/.
The first exact-target run with the new descriptor failed at run_smoke with
Failed to read firmware ... No such file or directory: the inventory built
the firmware into the shell's external CARGO_TARGET_DIR, but the smoke
script loads it from the worktree target/. No instruction ran. Retained
under 2026-11-15-missing-firmware-external-target-dir/. The rerun used
CARGO_TARGET_DIR=$(readlink -f target) and passed 3/3; the current result
is under ../../metrics/focaltech_ft9001/.
2026-11-15-negative-control-head-descriptor/ runs the same firmware on the
HEAD descriptor: FAIL 1/3, precise BusFault at 0x40002007 (RSR).