Skip to content

mimxrt798s negative control: flexcomm0 removed (2026-11-08)

Same firmware and smoke script, with flexcomm0 removed from the chip (the mimxrt798s.yaml copy here, loaded through a one-line system manifest chip: mimxrt798s.yaml with labwired test --system). FAIL 2/5: no UART bytes and the pass word at 0x20000004 is never written. Only the MULS word (written before any peripheral access) and the max_steps stop reason still hold. The first LP_FLEXCOMM access (the PSELID read at 0x40110FF8, PC 0x08000866) is unmapped and escalates to a HardFault (CFSR 0x8200 PRECISERR, BFAR 0x40110FF8). The UART and register checks therefore depend on the modelled flexcomm0.