STM32F072 USART shared IRQ failure before level-line fix
This is the committed exact-target evidence from the 2026-11-13 pre-fix measurement. The imported STM32F072 system booted and executed 4,000,000 instructions, but the USART3/USART4 shared IRQ 29 smoke failed because TXEIE did not consistently reach NVIC pending. The failure and its complete logs, UART output, JUnit result, simulator result, and snapshot are preserved here.
A further target-only reproduction at 06:53 UTC on the same pre-fix code again failed USART3 (quiet=1, pend=0, released=1). Its worktree metrics were replaced by the post-fix run; the committed pre-fix evidence above records the same failure class. The current pass is under docs/coverage/renode-onboarding/metrics/stm32f072/.