TIM1 capture/compare line + shared-line level reconcile (2026-11-21)
Guard: crates/core/tests/stm32/stm32_advanced_timer_irq_lines.rs
(cargo test -p labwired-core --test stm32 stm32_advanced_timer_irq_lines).
fixed.log— new descriptors, new bus reconcile: 3/3 pass.negative-control-old-descriptors.log— HEAD descriptors, new bus reconcile: every one of the 31 timer rows fails, and F103 ADC2 does not pend line 18. On this row (onboarding/stm32f072) TIM1 CC1G pended line 13, not TIM1_CC_IRQn = 14.negative-control-old-bus-reconcile.log— new descriptors, HEADbus/tick.rs+bus/device_hooks.rs: L476/L432 TIM1 update never shows on line 25, because idle TIM16 (same line) drops the level pend.stm32f042-smoke.log,stm32f072-smoke.log— the imported rows still pass 6/6 and 8/8 with the new descriptors (CLI built before the bus change).
IRQ numbers: vendor CMSIS device headers from the stm32duino core
(stm32f072xb.h: TIM1_BRK_UP_TRG_COM_IRQn = 13, TIM1_CC_IRQn = 14).