  • Exact imported system booted 4,000,000 instructions and emitted the expected USART2 RX gate result: both disabled-enable checks stayed clear, R,S arrived in order, and RXNE cleared after the drain.
  • The smoke failed only because its ordered UART assertion still expected the old summary value 0x0DC0FFFF; the firmware reported the new RX-gate summary value 0x0DC1FFFF.
  • Evidence is preserved here before retrying the target-only pipeline.