STM32F103 SPI1 first attempt: stimulus arrived after the read
The first --only stm32f103 run booted 50,000,000 instructions and passed 55
of 56 assertions. SPI1 TXE and RXNE IRQ assertion/release checks passed, but the
MAX31855 returned its documented power-on frame 0x01901600 (25 °C) before the
50 °C after_cycles stimulus was applied. The later stimulus cannot affect
that already completed transaction.
The next run removes the unnecessary temperature stimulus and checks the power-on frame directly. This directory retains the complete failed metrics, UART output, result, snapshot, JUnit report, and build/run logs.