Skip to content

STM32F103 continuous circular ADC DMA first run

The exact imported stm32f103 target booted 50,000,000 instructions to max_steps, but its new continuous circular ADC DMA smoke failed. The DMA half/complete flags, IRQ, two sample values, channel enable bit, and ADC EOC clear all matched. The final CNDTR read was zero, so the smoke emitted ADC1 F1 CONTINUOUS CIRCULAR LAPS=2 FLAGS=1 IRQ=1 RELOAD=0 SEQ=1 ENABLED=1 EOC_CLEAR=1 FAIL.

Command:

PATH=/usr/bin:/home/andrii/.cargo/bin:/usr/local/bin:/bin \
  CARGO_BUILD_JOBS=1 CARGO_INCREMENTAL=0 \
  /usr/bin/python3 scripts/run_renode_onboarding_inventory.py --only stm32f103

The attempt finished at 2026-11-18 21:38:01 UTC. It took 26.955 seconds, including a 12.829-second CLI build. All metrics, logs, UART, JUnit, result, and snapshot files from the failed attempt are preserved in this directory. The generated aggregate temporarily recorded 225/245 passes, 1 measured failure, and 19 not-run descriptors. The prior passing STM32F103 measurement is preserved separately in the older attempt history.