Skip to content

STM32F412 stale ADC smoke assertion (2026-11-18)

The exact imported system booted 800,000 instructions to max_steps. Six of seven observable smoke checks passed; the assertion for the prior ADC1 single conversion failed because it expected adc1 in1=000003FF gated=1 clock=1 eoc=1 ok, while the current shared firmware emitted adc1 in1=000003FF gated=1 clock=1 eoc=1 irq=1 clear=1 ok. The numeric ADC result, gate, clock, EOC, and new scan checks all passed. This is a stale UART expectation left behind by the shared ADC1 smoke gaining interrupt checks, not an ADC conversion or scan failure.

Preserved the run's metrics, build/run logs, UART, JUnit, result, and snapshot here. Correct the expected UART text, then rerun only stm32f412.