STM32F429 continuous ADC scan attempt — overrun
Command:
CARGO_BUILD_JOBS=1 CARGO_INCREMENTAL=0 python3 scripts/run_renode_onboarding_inventory.py --only stm32f429
The one-shot two-rank scan still passed. The first continuous-mode smoke used
EOCS=1 and attempted to drain every conversion in firmware. It observed the
expected channel sequence (IN1, IN2, IN1, IN2, IN1), but the ADC's 15-cycle
conversion cadence outpaced those MMIO reads and set OVR. The stop check also
raced a subsequent conversion because the ADC was disabled after clearing the
NVIC pending bit.
Captured UART:
This attempt remains a failure record. The follow-up checks EOCS=0, observes
the end-of-group interrupt three times while reading the final rank result,
then disables the ADC before clearing NVIC pending. ST RM0090 §13.3.8 specifies
that EOCS=0 reports EOC at the end of each regular group and CONT restarts
the sequence at the first selected channel.
Scoreboard aggregation was attempted, but the runner's Python environment did
not have PyYAML (generate_onboarding_scoreboard.py exited 2); the existing
aggregate was therefore left untouched.