STM32F429 continuous ADC scan attempt — stop boundary
Command:
CARGO_BUILD_JOBS=1 CARGO_INCREMENTAL=0 PATH=/usr/bin:/home/andrii/.cargo/bin:/usr/local/bin:/bin /usr/bin/python3 scripts/run_renode_onboarding_inventory.py --only stm32f429
The imported platform booted 800,000 instructions. The one-shot scan passed;
the continuous scan observed three group-end results of 0x07FF, an IRQ, and
no OVR. The stop assertion still found EOC set immediately after disabling the
ADC, consistent with a conversion completing at the stop boundary:
The follow-up disables the ADC, clears any completion flag that latched before the disable took effect, confirms ADON reads clear, and then verifies EOC stays clear for 64 cycles. This attempt remains preserved as a measured failure. The generated scoreboard records 226 booted; 225 boot-and-smoke passed; 1 failed; 19 not run.