STM32F429 ADC scan attempt 1

The two scan results were correct (IN1=0x03FF, IN2=0x07FF), but the firmware cleared NVIC pending after rank 1 and then expected a second pending bit after rank 2. The F4 ADC conversion interval in this model is 15 cycles, so the two peripheral events can coalesce into the same NVIC pending bit before the firmware clears it. The check therefore did not isolate two separate IRQ entries.

The smoke now checks that EOC is visible for each rank, that ADC1 IRQ 18 is pending at the first EOC and remains pending through rank 2, and that software can release pending after reading DR and clearing NVIC. The peripheral unit tests check that each rank independently returns an EOC interrupt request.