BMI270 SPI interrupt delivery
The native SPI kit now binds INT1 and INT2 output roles through the same
AttachCtx pad-binding path as declarative devices. The model queues role
names; the bus resolves them to the placement's int1_pin / int2_pin.
Previously the kit queued GPIO labels without registering any pad bindings,
so its protocol-level DRDY tests did not establish delivery to an MCU.
The optional interrupt pads remain optional. A supplied pin must be a nonempty string and resolve to a real input; null, booleans, integers, arrays, empty/whitespace strings and unknown pads fail attachment.
On 12 November 2026, 35 focused cases passed: 17 BMI270 SPI protocol/factory cases, 15 existing generic device-pin cases and three I2C wrapper cases. The new positive fixture initializes the exact 328-byte Bosch image, maps DRDY first to INT1 then INT2, and reads the actual STM32L476 GPIO input words through the bus. It also proves status-read clear and reset parking. SPI frames are driven directly into the attached device to isolate the factory, controller-drain and GPIO delivery path from MCU SPI register behavior.
This base lacks the pending RP bank-aware input-resolution fix. Its existing RP factory case therefore tests explicit CS and unpowered bus behavior with no interrupt declared. Native RP GPIO13 delivery still requires the separate combined-runtime controller test. Dynamic VDD/VDDIO qualification is a separate pending gate; this receipt does not establish powered native-board startup, FIFO/auxiliary behavior or physical sensor fidelity.